327-184
Coils and Transformers
TRANSFORMER,POWER
327-184
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Hole Diameter
0.128 inches nominal
-
Frequency Rating
400.0 hertz nominal
-
Input-Output Phase Relationship
single phase to single phase
-
Body Length
1.625 inches nominal
-
Body Width
0.938 inches maximum
-
Body Height
0.875 inches maximum
-
Maximum Operating Temp
125.0 deg celsius
-
Inclosure Type
open
-
Winding Function And Quantity
1 primary and 1 secondary
-
Winding Tap Location
center tap
-
Reliability Indicator
not established
-
Overall Height
1.063 inches nominal
-
Distance Between Mounting Facility Centers
1.375 inches nominal
-
Mounting Facility Quantity
2
-
Mounting Method
flange and unthreaded hole
-
Winding Operating Current
25.0 milliamperes ac maximum
-
Winding Operating Voltage
115.00 ac volts nominal
-
Winding Operating Voltage
56.00 ac volts nominal
-
Terminal Type And Quantity
5 wire lead