900056-0010
Resistors
RESISTOR,VARIABLE,WIRE WOUND,PRECISION
900056-0010
RESISTOR,VARIABLE,WIRE WOUND,PRECISION
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mechanical Backlash In Deg Angular Rotation
0.05
-
Shaft Radial Play
0.0005 inches
-
Electrical Resistance Per Section
100.0 percent, rated amperes c and better finish
-
Pilot Diameter Runout
0.0005 inches
-
Undercut Width
0.0780 inches minimum
-
Resistance Tolerance Per Section In Percent
-5.0/+5.0 all sections
-
Maximum Starting Torque
2.30 inch-ounces
-
Actuator Travel Control Feature
stops
-
Body Diameter
1.830 inches maximum
-
Power Dissipation Rating Per Section In Watts
2.0 free air all sections
-
Function Characteristic Per Section
all sections graph
-
Shaft Style
round, slotted
-
Shaft Bearing Type
ball
-
Section Quantity
3
-
Temp Coefficient Of Resistance Per Section In Ppm Per Deg Celsius
-20.0/+20.0 all sections
-
Test Data Document
06481-900056-10 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Maximum Running Torque
1.80 inch-ounces
-
Body Length
2.500 inches maximum
-
Mounting Lip Depth
0.0620 inches nominal
-
Mounting Lip Diameter
1.8120 inches maximum
-
Function Conformity Tolerance Per Section
-0.05/+0.05 all sections
-
Fixed Tap Quantity Per Section
1 all sections
-
Body Style
cylindrical servo mounted
-
Ambient Temp In Deg Celsius Per Section At Full Rated Power
40.0 all sections
-
Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation
1800.0 all sections
-
Rotary Actuator Travel In Angular Deg
3600.0 nominal
-
Pilot Length
0.0620 inches nominal
-
Tap Location Tolerance Per Section
-1.0/+1.0 deg angular rotation all sections
-
Actuator Type
single shaft
-
Reliability Indicator
not established
-
Ambient Temp In Deg Celsius Per Section At Zero Percent Rated Power
130.0 all sections
-
Electrical Resistance Per Section
30.0 percent, rated amperes c and better industrial clears
-
Shaft Length
0.812 inches nominal
-
Mounting Method
clamp ring
-
Shaft Runout
0.0005 inches
-
Electrical Resistance Per Section
30.0 percent, rated amperes c and better select
-
Shaft End Play
0.003 inches
-
Pilot Diameter
1.5620 inches maximum
-
Terminal Type And Quantity
12 turret
-
Function Conformity Per Section
all sections terminal base linearity
-
Shaft Diameter
0.1248 inches maximum
-
Terminal Location
radially positioned over more than half the circumference
-
Undercut Diameter
1.625 inches maximum