40941
Coils and Transformers
TRANSFORMER,POWER
40941
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Quantity
4 single group
-
Winding Operating Voltage
23.60 ac volts nominal single component 2nd secondary
-
Winding Operating Current
1.1 amperes dc nominal single component 1st secondary
-
Winding Power Rating
26.0 volts-amperes single component 1st secondary
-
Winding Operating Current
1.1 amperes dc nominal single component 2nd secondary
-
Unpackaged Unit Weight (Non-Core)
30.000 pounds
-
Terminal Type And Quantity
24 solder stud
-
Overall Height
8.630 inches maximum
-
Mounting Method
threaded stud single group
-
Body Width
5.000 inches maximum
-
Winding Power Rating
26.0 volts-amperes single component 2nd secondary
-
Center To Center Distance Between Mounting Facilities Parallel To Width
3.250 inches nominal single mounting facility single center group
-
Body Height
7.000 inches maximum
-
Winding Operating Voltage
115.00 ac volts nominal single component single primary and 126.00 ac volts nominal single component single primary and 120.00 ac volts nominal single component single primary and 109.00 ac volts nominal single component single primary and 132.00 ac volts
-
~1
nominal single component single primary
-
Frequency Rating
57.0 hertz minimum single component and 63.0 hertz maximum single component
-
Winding Power Rating
31.2 volts-amperes single component 4th secondary
-
Thread Direction (Non-Core)
err-070
-
Winding Power Rating
31.2 volts-amperes single component 3rd secondary
-
Winding Operating Voltage
23.60 ac volts nominal single component 1st secondary
-
Nominal Thread Size
0.250 inches single group
-
Thread Series Designator
unc single group
-
Inclosure Type
hermetically sealed
-
Winding Operating Voltage
44.50 ac volts nominal single component 4th secondary
-
Winding Shielding Method
internal shield grounded to inclosure single component
-
Maximum Operating Temp
130.0 deg celsius
-
Special Features
one primary and nine secondaries
-
Input-Output Phase Relationship
single phase to single phase single component
-
Thread Class (Non-Core)
err-070
-
Winding Operating Current
700.0 milliamperes dc nominal single component 4th secondary
-
Winding Function And Quantity
1 primary single component and 9 secondary single component
-
Reliability Indicator
not established
-
Winding Operating Current
700.0 milliamperes dc nominal single component 3rd secondary
-
Winding Operating Voltage
44.50 ac volts nominal single component 3rd secondary
-
Body Length
6.000 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Length
4.750 inches nominal single mounting facility single center group