1021154
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
1021154
Telair International Incorporated
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Inclosure Type
encased
-
Principal Circuitry Type Per Function
inductance-capacitance blank
-
Functional Terminal Type And Quantity
1 wire lead output 2nd function
-
Power Line Frequency Rating Per Function In Hertz
400.0 blank
-
Operating Current Rating Per Function In Amps
0.52 blank
-
Test Data Document
98889-1021154 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Operating Temp Range
-65.0/+160.0 deg fahrenheit
-
Average Life Rating In Hours
1000.0
-
Functional Terminal Type And Quantity
1 wire lead input 1st function
-
Maximum Dielectric Withstanding Ac Rms Voltage
500.0 volts at sea level
-
Operating Voltage Rating And Type Per Function
120.0 volts ac blank