W91D15-0-15

Circuit Breakers

CIRCUIT BREAKER

W91D15-0-15

5925-00-905-9144

5925 - Circuit Breakers

Tyco Electronics Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Switch Contact Arrangement

    single pole, double throw

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Body Style

    single pole type

  • Trip Release Method

    magnetic-hydraulic single location

  • Inclosure Protection Type For Which Designed

    fungus resistant and explosion resistant and moisture resistant

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Trip Release Characteristic

    instantaneous single location

  • Body Length

    2.490 inches minimum and 2.510 inches maximum

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Switch Terminal Type

    tab w/screw

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    120.0 single location

  • Terminal Type And Quantity

    2 threaded stud

  • Fragility Factor

    moderately rugged

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Mounting Surface To Terminal End Distance

    2.461 inches minimum and 2.481 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Switch Current Rating And Type In Amps

    5.0 ac and 1.0 dc

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes dc single location

  • Actuator Function

    trip-reset

  • Switch Voltage Rating And Type In Volts

    125.0 ac and 50.0 dc

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Circuit Protection Type

    overcurrent single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...