260-4015-360

Circuit Breakers

CIRCUIT BREAKER

260-4015-360

5925-00-905-9686

5925 - Circuit Breakers

Rockwell Collins Inc.

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Iii Unpackaged Unit Weight

    14.250 ounces

  • Iii Fragility Factor

    moderately rugged

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Trip Release Characteristic

    time delay all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.735 inches minimum and 0.765 inches maximum

  • Case Material

    plastic

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Body Length

    2.485 inches minimum and

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Actuator Function

    trip-reset

  • Iii Arc Quenching Method

    magnetic blowout

  • Terminal Type And Quantity

    6 threaded stud

  • Thread Series Designator

    unc

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Trip Release Method

    magnetic all locations

  • Frequency In Hertz

    400.0 all locations

  • Iii Special Handling Feature

    magnetic

  • Center To Center Distance Between Terminals Parallel To Width

    0.735 inches minimum and 0.765 inches maximum

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant and shock resistant and humidity resistant and salt spray proof

  • Actuator Position Designation

    at each pole

  • Body Width

    2.299 inches minimum and 2.301 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac all locations

  • Internal Trip Release Configuration

    series trip all locations

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Manual Actuator Type And Quantity

    3 toggle

  • Switch Location And Position Designation

    external at each pole

  • Switch Current Rating And Type In Amps

    2.5 ac and 1.0 dc

  • Main Contact Tripping Mechanism Type

    trip free

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 200 pct and 1.200 maximum at 200 pct all locations

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Nominal Thread Size

    0.138 inches

  • Switch Terminal Type

    tab, solder lug

  • Reset Method

    manual

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Mounting Surface To Terminal End Distance

    2.409 inches minimum and 2.533 inches maximum

  • Iii Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Test Data Document

    13499-260-4015 drawing

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.047 inches minimum and 2.077 inches maximum

  • Circuit Protection Type

    overcurrent all locations

  • Body Style

    8c multipole-multiple actuator type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...