2159405-1
Switches
SWITCH,ROTARY
2159405-1
SWITCH,ROTARY
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Test Data Document
81349-mil-s-3786 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
First Flat Length
0.380 inches nominal single actuator
-
Contact Load Current Rating
150.0 milliamperes resistive load ac at sea level
-
Thread Class
2a single mounting facility
-
Terminal Type
tab, solder lug
-
Overall Width
1.430 inches nominal
-
Flat Height
0.219 inches nominal single actuator
-
Individual Section Quantity
1
-
Nonturn Device Type
tab at 9:00 o'clock
-
Switch Actuator Positioning Increment
30.0 degrees single actuator
-
Switch Actuator Indexing Position Quantity
5 single actuator
-
Overall Length
1.810 inches maximum
-
Throw Quantity
5 single section front
-
Switch Actuator Stop Device Type
fixed stop single actuator
-
Nonturn Device Radius
0.437 inches nominal at 9:00 o'clock
-
Overall Height
1.500 inches nominal
-
Pole Quantity
2 single section rear
-
Contact Voltage Rating In Volts
110.0 ac at sea level
-
Switch Contact Basic Design
nonpile-up symmetrical
-
Thread Series Designator
unef single mounting facility
-
Style Designator
circular wafer, bushing mount
-
Pole Quantity
1 single section front
-
Throw Quantity
5 single section rear
-
Err Default
err default
-
Contact Switching Action
breaks before makes single section front
-
Shaft Flat/Slot Angular Location
270.0 degrees from nonturn device single actuator
-
Nominal Thread Size
0.375 inches single mounting facility
-
Shaft Length
0.810 inches nominal single actuator
-
Shaft Type
round, flatted single actuator
-
Contact Load Current Rating
2.0 milliamperes resistive load dc at sea level
-
Shaft Diameter
0.248 inches nominal single actuator
-
Contact Switching Action
breaks before makes single section rear
-
Contact Voltage Rating In Volts
15.0 dc at sea level
-
Mounting Method
threaded bushing single mounting facility
-
~1
data on certain environmental and performance