2258974P19
Circuit Breakers
CIRCUIT BREAKER
2258974P19
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Reset Method
manual
-
Ultimate Trip Time Per Pole In Seconds
4.000 minimum and 40.000 maximum single location
-
Trip Release Method
magnetic single location
-
Circuit Protection Type
overcurrent single location
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location
-
Thread Quantity Per Inch
32
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Pole Quantity
1
-
Mounting Surface To Terminal End Distance
1.605 inches nominal
-
Center To Center Distance Between Terminals Parallel To Length
0.875 inches nominal
-
Body Width
0.640 inches nominal
-
Body Length
1.531 inches nominal
-
Bushing Length
0.340 inches nominal
-
Body Style
2a single pole type
-
Reference Number Differentiating Characteristics
as differentiated by special test features
-
Thread Series Designator
unef
-
Manufacturers Code
10001
-
Special Test Features
navord od36190
-
Nominal Thread Size
0.375 inches
-
Actuator Position Designation
at pole one
-
Manual Actuator Type And Quantity
1 toggle
-
Main Contact Tripping Mechanism Type
trip free
-
Terminal Type And Quantity
2 wire hook
-
Design Control Reference
2258974p19
-
Inclosure Protection Type For Which Designed
hermetically sealed
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.600 minimum at 200 pct and 6.000 maximum at 200 pct and 0.085 minimum at 300 pct and 1.800 maximum at 300 pct and 0.015 minimum at 400 pct and 0.600 maximum at 400 pct single location
-
Internal Trip Release Configuration
series trip single location
-
Actuator Function
reset
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Trip Release Characteristic
time delay single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 dc single location
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes dc single location
-
Case Material
metal