977-6006
Resistors
RESISTOR,VARIABLE,WIRE WOUND,PRECISION
977-6006
RESISTOR,VARIABLE,WIRE WOUND,PRECISION
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fixed Tap Quantity Per Section
2 1st section
-
Mounting Lip Diameter
0.7450 inches minimum and 0.7550 inches maximum
-
Shaft Runout
0.001 inches
-
Body Length
1.145 inches minimum and 1.155 inches maximum
-
Pilot Length
0.0570 inches minimum and 0.0670 inches maximum
-
Fixed Tap Quantity Per Section
2 2nd section
-
Body Diameter
0.745 inches minimum and 0.775 inches maximum
-
Shaft Length
0.375 inches nominal
-
Electrical Resistance Per Section
1.0 percent, rated amperes c and better finish
-
Undercut Width
0.0570 inches minimum
-
Terminal Location
radially positioned over more than half the circumference
-
Function Conformity Tolerance Per Section
-0.35/+0.35 all sections
-
Ambient Temp In Deg Celsius Per Section At Full Rated Power
100.0 all sections
-
Terminal Type And Quantity
10 turret
-
Electrical Resistance Per Section
500.0 ohms c and better industrial clears
-
Effective Electrical Rotation In Deg Angular Rotation
352.0 nominal
-
Overall Length
1.611 inches maximum
-
Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation
40.4 1st section and 196.2 1st section
-
Maximum Starting Torque
0.20 inch-ounces
-
Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation
40.4 2nd section and 80.8 2nd section
-
Pilot Diameter Runout
0.001 inches
-
Shaft Style
round
-
Shaft Radial Play
0.001 inches
-
Body Style
cylindrical servo mounted
-
Lateral Runout
0.001 inches
-
Resistance Tolerance Per Section In Percent
-3.0/+3.0 all sections
-
Maximum Running Torque
0.20 inch-ounces
-
Undercut Diameter
0.651 inches minimum and 0.661 inches maximum
-
Rotary Actuator Travel In Angular Deg
360.0 nominal
-
Pilot Diameter
0.6245 inches minimum and 0.6250 inches maximum
-
Function Conformity Per Section
all sections independent linearity
-
Tap Location Tolerance Per Section
-1.0/+1.0 deg angular rotation all sections
-
Actuator Type
single shaft
-
Reliability Indicator
not established
-
Actuator Travel Control Feature
continuous motion
-
Mounting Method
clamp ring
-
Mounting Lip Depth
0.0570 inches minimum and 0.0670 inches maximum
-
Shaft Diameter
0.124 inches minimum and 0.125 inches maximum
-
Section Quantity
2
-
Power Dissipation Rating Per Section In Watts
0.5 free air all sections
-
Shaft Bearing Type
ball
-
Function Characteristic Per Section
all sections linear
-
Temp Coefficient Of Resistance Per Section In Ppm Per Deg Celsius
-20.0/+20.0 all sections