AS58091

Circuit Breakers

CIRCUIT BREAKER

AS58091

5925-00-912-8343

5925 - Circuit Breakers

Society Of Automotive Engineers Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Mounting Surface To Terminal End Distance

    1.812 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0 single location

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Inclosure Protection Type For Which Designed

    corrosion resistant and moisture resistant and explosion proof and dustproof and sand resistant and fungus resistant

  • Trip Release Method

    thermal single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Manual Actuator Type And Quantity

    1 push-pull

  • Pole Quantity

    1

  • Case Material

    metal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location

  • Center To Center Distance Between Terminals Parallel To Length

    0.672 inches minimum and 0.734 inches maximum

  • Internal Trip Release Configuration

    series trip single location

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location and 28.0 dc single location

  • Trip Release Characteristic

    time delay single location

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Terminal Type And Quantity

    2 screw

  • Main Contact Tripping Mechanism Type

    trip free

  • Bushing Length

    0.273 inches minimum and 0.293 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac single location and 1.0 amperes dc single location

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Body Length

    0.780 inches maximum

  • Specification/Standard Data

    96906-ms22073 government standard

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    800.0 ac single location and 2000.0 dc single location

  • Body Width

    0.593 inches maximum

  • Nominal Thread Size

    0.469 inches

  • Thread Series Designator

    uns

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Test Data Document

    81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • ~1

    data on certain environmental and performance

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...