08-00433-008
Filters and Networks
FILTER,BAND PASS
08-00433-008
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Reference Frequency Per Function
90.0 single radio interference two phase to two phase
-
Inclosure Type
hermetically sealed
-
Functional Terminal Type And Quantity
1 pin output 2nd function
-
Discrimination At Specified Frequencies Per Function In Decibels
8.0 maximum 1st band pass and 30.0 minimum 1st band pass and 8.0 maximum 1st band pass and 30.0 minimum 1st band pass
-
Source Impedance Rating Per Function
600.0 ohms 2nd band pass
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
3.750 inches nominal
-
Specified Frequencies Of Discrimination Per Function
92.00 kilohertz 2nd band pass and 88.00 kilohertz 2nd band pass and 85.00 kilohertz 2nd band pass and 98.00 kilohertz 2nd band pass
-
Load Impedance Per Function
2.0 kilohms 1st band pass
-
Body Width
1.250 inches nominal
-
Vibration Resistance Range In Hertz
+10.0/+2000.0
-
Frequency Band Width Per Function
88.00 kilohertz 1st band pass and 92.00 kilohertz 1st band pass
-
Body Material
metal
-
Load Impedance Per Function
2.0 kilohms 2nd band pass
-
Body Height
3.000 inches nominal
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Overall Height
3.360 inches nominal
-
Frequency Band Width Per Function
88.00 kilohertz 2nd band pass and 92.00 kilohertz 2nd band pass
-
Average Life Rating In Hours
10000.0
-
Insertion Loss At Reference Frequency Per Function In Decibels
8.0 1st band pass
-
Mounting Facility Type And Quantity
4 unthreaded hole
-
Insertion Loss At Reference Frequency Per Function In Decibels
8.0 2nd band pass
-
Reference Frequency Per Function
90.0 single radio interference pulses per second
-
Discrimination At Specified Frequencies Per Function In Decibels
30.0 minimum 2nd band pass and 8.0 maximum 2nd band pass and 8.0 maximum 2nd band pass and 30.0 minimum 2nd band pass
-
Source Impedance Rating Per Function
600.0 ohms 1st band pass
-
Unpackaged Unit Weight
1.300 pounds
-
Specified Frequencies Of Discrimination Per Function
92.00 kilohertz 1st band pass and 85.00 kilohertz 1st band pass and 88.00 kilohertz 1st band pass and 98.00 kilohertz 1st band pass
-
Functional Terminal Type And Quantity
2 pin ground 3rd function
-
Body Length
4.500 inches nominal
-
Unthreaded Mounting Hole Diameter
0.160 inches nominal
-
Operating Temp Range
-40.0/+71.0 deg celsius
-
Functional Terminal Type And Quantity
1 pin input 1st function