4MC2-6-30

Circuit Breakers

CIRCUIT BREAKER

4MC2-6-30

5925-00-912-9134

5925 - Circuit Breakers

Sensata Technologies Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Pitch Diameters

    p0.1177/p0.1214 inches

  • Body Style

    single pole type

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    1

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes dc

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc

  • Circuit Protection Type

    overcurrent

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct and 8.500 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    dustproof and fungus proof

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    2 threaded stud

  • Body Length

    2.500 inches nominal

  • Body Width

    0.750 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Boss Height

    0.140 inches nominal

  • Mounting Surface To Terminal End Distance

    2.611 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Special Handling Feature

    magnetic

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc

  • Trip Release Method

    magnetic-hydraulic

  • Trip Release Characteristic

    time delay

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...