APL1-533-450

Circuit Breakers

CIRCUIT BREAKER

APL1-533-450

5925-00-912-9135

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    2.500 inches minimum and 2.530 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.930 inches minimum and 1.950 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Fragility Factor

    moderately rugged

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Special Handling Feature

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc

  • Trip Release Method

    magnetic

  • Trip Release Characteristic

    time delay

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Terminal Type And Quantity

    2 threaded stud

  • Precious Material And Location

    terminals and nuts and washers silver

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct and 10.000 maximum at 200 pct

  • Actuator Position Designation

    at pole one

  • Actuator Function

    trip w/separate reset

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Ultimate Trip Time Per Pole In Seconds

    12.000 minimum and 40.000 maximum

  • Thread Series Designator

    unc

  • Precious Material

    silver

  • Unpackaged Unit Weight

    0.280 pounds

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip

  • Circuit Protection Type

    overcurrent

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc

  • Thread Quantity Per Inch

    32

  • Storage Type

    general purpose warehouse

  • Pole Quantity

    1

  • Mounting Surface To Terminal End Distance

    2.408 inches minimum and 2.552 inches maximum

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Case Material

    plastic

  • Body Width

    0.740 inches minimum and 0.760 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...