7274-12 1-2

Circuit Breakers

CIRCUIT BREAKER

7274-12 1-2

5925-00-913-3345

5925 - Circuit Breakers

Sensata Technologies Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Continuous Load Current Rating Per Pole

    500.0 milliamperes ac single location and 500.0 milliamperes dc single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 single location

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 ac single location and 1000.0 dc single location

  • Inclosure Protection Type For Which Designed

    dustproof and fungus resistant

  • Nominal Thread Size

    0.469 inches

  • Center To Center Distance Between Terminals Parallel To Length

    0.593 inches nominal

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Mounting Surface To Terminal End Distance

    1.420 inches maximum

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 push button

  • Terminal Type And Quantity

    2 screw

  • Thread Quantity Per Inch

    32

  • Body Width

    0.562 inches nominal

  • Circuit Protection Type

    overcurrent single location

  • Bushing Length

    0.359 inches nominal

  • Trip Release Method

    thermal single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Pole Quantity

    1

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location

  • Internal Trip Release Configuration

    series trip single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 28.0 dc single location

  • Body Length

    1.115 inches nominal

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...