Y63E880239-001

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

Y63E880239-001

5915-00-914-3232

5915 - Filters and Networks

Gyrodyne Co Of America Inc

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Operating Current Rating Per Function In Amps

    2.5 3rd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 1st radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.250 inches nominal

  • Maximum Voltage Drop Per Function

    500.0 millivolts ac 6th radio interference

  • Maximum Voltage Drop Per Function

    500.0 millivolts ac 5th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 3rd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 2nd radio interference

  • Inclosure Type

    encased

  • Maximum Temp Rise

    25.0 deg celsius

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Maximum Voltage Drop Per Function

    500.0 millivolts ac 4th radio interference

  • Functional Terminal Type And Quantity

    1 connector, receptacle output 2nd function

  • Mounting Facility Type And Quantity

    4 threaded stud

  • Operating Current Rating Per Function In Amps

    2.5 2nd radio interference

  • Load Impedance Per Function

    50.0 ohms 6th radio interference

  • Maximum Voltage Drop Per Function

    500.0 millivolts ac 3rd radio interference

  • Maximum Voltage Drop Per Function

    500.0 millivolts ac 2nd radio interference

  • Load Impedance Per Function

    50.0 ohms 5th radio interference

  • Maximum Voltage Drop Per Function

    500.0 millivolts ac 1st radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Operating Temp Range

    -40.0/+55.0 deg celsius

  • Operating Voltage Rating And Type Per Function

    115.0 volts ac 3rd radio interference 3rd function

  • Operating Current Rating Per Function In Amps

    2.5 1st radio interference

  • Nominal Thread Size

    0.164 inches

  • Mounting Facility Screw Thread Series Designator

    unc

  • Operating Voltage Rating And Type Per Function

    22.0 volts ac 6th radio interference 6th function

  • Body Length

    2.750 inches nominal

  • Operating Current Rating Per Function In Amps

    8.0 6th radio interference

  • Operating Current Rating Per Function In Amps

    2.0 5th radio interference

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Operating Current Rating Per Function In Amps

    2.0 4th radio interference

  • Functional Terminal Type And Quantity

    2 tab, solder lug ground 3rd function

  • Operating Voltage Rating And Type Per Function

    115.0 volts ac 2nd radio interference 2nd function

  • Body Height

    5.125 inches nominal

  • Output Terminal Identification

    ms3122e-18-11sw

  • Operating Voltage Rating And Type Per Function

    26.0 volts ac 5th radio interference 5th function

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Output Terminal Manufacturer Code

    96906

  • Source Impedance Rating Per Function

    50.0 ohms 6th radio interference

  • Style Designator

    rectangular terminal/terminals on opposite surfaces

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Operating Voltage Rating And Type Per Function

    26.0 volts ac 4th radio interference 4th function

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference

  • Body Material

    metal

  • Body Width

    1.812 inches nominal

  • Operating Voltage Rating And Type Per Function

    115.0 volts ac 1st radio interference 1st function

  • Special Features

    8 functions

  • Functional Terminal Type And Quantity

    9 tab, solder lug input 1st function

  • Body Surface Treatment

    tin

  • Power Line Frequency Rating Per Function In Hertz

    400.0 6th radio interference

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 5th radio interference

  • Overall Height

    5.681 inches nominal

  • Power Line Frequency Rating Per Function In Hertz

    400.0 4th radio interference

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.312 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...