APL-1-1-41-502

Circuit Breakers

CIRCUIT BREAKER

APL-1-1-41-502

5925-00-918-1483

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Terminal Type And Quantity

    2 threaded stud

  • Case Material

    plastic

  • Unpackaged Unit Weight

    3.700 ounces

  • Body Width

    0.750 inches maximum

  • Body Length

    2.480 inches minimum and 2.500 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location

  • Inclosure Protection Type For Which Designed

    shock resistant and salt spray proof and moisture resistant and vibration resistant

  • Body Style

    single pole type

  • Frequency In Hertz

    400.0 single location

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Trip Release Characteristic

    time delay single location

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Pole Quantity

    1

  • Circuit Protection Type

    overcurrent single location

  • Boss Height

    0.135 inches minimum and 0.165 inches maximum

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.200 minimum at 200 pct single location and 2.000 maximum at 200 pct single location

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Mounting Surface To Terminal End Distance

    2.491 inches maximum

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1500.0 ac single location

  • Thread Series Designator

    unc

  • Center To Center Distance Between Terminals Parallel To Length

    1.925 inches minimum and 1.955 inches maximum

  • Special Handling Feature

    magnetic

  • Trip Release Method

    magnetic single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...