AM12-15-77

Circuit Breakers

CIRCUIT BREAKER

AM12-15-77

5925-00-918-1491

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • ~1

    single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 150 pct single location and 0.800 maximum at 200 pct single location and 0.250 minimum at 200 pct single location and 0.100 minimum at 300 pct single location and 1.100 maximum at 150 pct single location and 0.200 maximum at 300 pct

  • Actuator Function

    reset

  • Trip Release Method

    magnetic single location

  • Thread Series Designator

    unc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Reset Method

    manual

  • Internal Trip Release Configuration

    relay trip single location

  • Boss Height

    0.150 inches nominal

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Body Length

    2.530 inches nominal

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Body Width

    0.760 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac single location

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Nominal Thread Size

    0.138 inches

  • Inclosure Protection Type For Which Designed

    explosion proof

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Terminal Type And Quantity

    2 threaded stud

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Case Material

    plastic

  • Trip Release Characteristic

    instantaneous single location and time delay single location

  • Mounting Surface To Terminal End Distance

    2.480 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.460 inches nominal

  • Frequency In Hertz

    60.0 single location

  • Body Style

    single pole type

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...