1200-015-10
Circuit Breakers
CIRCUIT BREAKER
1200-015-10
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Trip Release Method
thermal single location
-
Manual Actuator Type And Quantity
1 push-pull
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Pole Quantity
1
-
Internal Trip Release Configuration
series trip single location
-
Nominal Thread Size
0.138 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.822 inches maximum
-
Trip Release Characteristic
time delay single location
-
Main Contact Tripping Mechanism Type
trip free
-
Frequency In Hertz
400.0 single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac single location and 6000.0 dc single location
-
Body Style
single pole type
-
Body Length
2.187 inches maximum
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location and 30.0 dc single location
-
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac single location and 10.0 amperes dc single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
-
Trip Delay Time In Seconds Per Rated Continuous Current
45.000 minimum at 150 pct single location and 15.000 minimum at 200 pct single location and 105.000 maximum at 150 pct single location and 50.000 maximum at 200 pct single location
-
Bushing Length
0.250 inches maximum
-
Body Width
0.750 inches maximum
-
Case Material
plastic
-
Thread Series Designator
unc
-
Reset Method
manual
-
Center To Center Distance Between Terminals Parallel To Length
1.187 inches nominal
-
Trip Release Ambient Temp Rating
25.0 deg celsius maximum single location
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Terminal Type And Quantity
2 screw
-
Mounting Facility Type And Quantity
2 threaded hole
-
Thread Quantity Per Inch
32
-
Mounting Surface To Terminal End Distance
2.000 inches maximum
-
Circuit Protection Type
overcurrent single location