AM12HKMG6-25-125VAC60C4
Circuit Breakers
CIRCUIT BREAKER
AM12HKMG6-25-125VAC60C4
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 minimum at 150 pct single location and 1.400 minimum at 300 pct single location and 30.000 maximum at 150 pct single location and 10.000 maximum at 200 pct single location and 4.000 minimum at 200 pct single location and 4.000 maximum at 300 pct
-
~1
single location
-
Trip Release Characteristic
time delay single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Ultimate Trip Time Per Pole In Seconds
18.000 minimum single location and 70.000 maximum single location
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.052 inches minimum and 2.072 inches maximum
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac single location
-
Body Style
single pole type
-
Manual Actuator Type And Quantity
2 toggle
-
Trip Release Method
magnetic-hydraulic single location
-
Frequency In Hertz
60.0 single location
-
Auxiliary Switch Function And Quantity
1 alarm
-
Operating Voltage Type And Rating Per Pole In Volts
125.0 ac single location
-
Terminal Type And Quantity
2 threaded stud
-
Body Length
2.490 inches minimum and 2.510 inches maximum
-
Boss Height
0.130 inches minimum and 0.150 inches maximum
-
Switch Location And Position Designation
internal at pole one
-
Case Material
plastic
-
Fragility Factor
moderately rugged
-
Inclosure Protection Type For Which Designed
explosion resistant and fungus resistant and moisture resistant
-
Switch Terminal Type
tab, solder lug
-
Thread Series Designator
unc
-
Maximum Continuous Load Current Rating Per Pole
25.0 amperes ac single location
-
Reset Method
manual
-
Mounting Surface To Terminal End Distance
2.461 inches minimum and 2.481 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
1.928 inches minimum and 1.948 inches maximum
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Mounting Facility Type And Quantity
2 threaded hole
-
Thread Quantity Per Inch
32
-
Body Width
0.740 inches minimum and 0.760 inches maximum
-
Circuit Protection Type
overcurrent single location
-
Switch Contact Arrangement
single pole, double throw
-
Switch Current Rating And Type In Amps
2.5 ac and 1.0 dc
-
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc
-
Pole Quantity
1
-
Internal Trip Release Configuration
series trip single location
-
Nominal Thread Size
0.138 inches