Technical Characteristics

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.230 minimum at 200 pct and 0.650 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Switch Terminal Type

    tab,solder lug

  • Thread Series Designator

    unc

  • Switch Location And Position Designation

    internal at pole one

  • Internal Trip Release Configuration

    series trip

  • Manual Actuator Type And Quantity

    3 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0

  • Circuit Protection Type

    overcurrent

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac

  • Storage Type

    general purpose warehouse

  • Arc Quenching Method

    magnetic blowout

  • Mounting Surface To Terminal End Distance

    2.611 inches nominal

  • Boss Height

    0.140 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Case Material

    plastic

  • Body Width

    2.250 inches nominal

  • Body Style

    multipole-multiple actuator type

  • Unpackaged Unit Weight

    14.000 ounces

  • Frequency In Hertz

    400.0

  • Switch Voltage Rating And Type In Volts

    250.0 ac

  • Switch Current Rating And Type In Amps

    2.5 ac

  • Nominal Thread Size

    0.138 inches

  • Auxiliary Switch Function And Quantity

    1 alarm

  • External Actuator Linkage Arrangement

    one,two,and three linked

  • Actuator Position Designation

    at each pole

  • Actuator Function

    trip-reset

  • Reset Method

    manual

  • Trip Release Characteristic

    time delay

  • Trip Release Method

    magnetic-hydraulic

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Pole Quantity

    3

  • Fragility Factor

    moderately rugged

  • Switch Contact Arrangement

    single pole,double throw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Body Length

    2.500 inches nominal

  • Terminal Type And Quantity

    6 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...