FSR-W-50B3
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
FSR-W-50B3
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Power Line Frequency Rating Per Function In Hertz
60.0 3rd radio interference
-
Inclosure Type
hermetically sealed
-
Functional Terminal Type And Quantity
3 tab, solder lug input 1st function
-
Operating Voltage Rating And Type Per Function
277.0 volts ac 3rd radio interference 3rd function and 600.0 volts dc 3rd radio interference 3rd function
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Operating Temp Range
-55.0/+85.0 deg celsius
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Maximum Voltage Drop Per Function
2.77 volts ac 1st radio interference and 6.0 volts dc 1st radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference
-
Maximum Temp Rise
25.0 deg celsius
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Maximum Voltage Drop Per Function
2.77 volts ac 2nd radio interference and 6.0 volts dc 2nd radio interference
-
Maximum Voltage Drop Per Function
2.77 volts ac 3rd radio interference and 6.0 volts dc 3rd radio interference
-
Overall Length
39.000 inches nominal
-
Body Material
metal
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Operating Current Rating Per Function In Amps
50.0 1st radio interference
-
Functional Terminal Type And Quantity
3 tab, solder lug output 2nd function
-
Operating Current Rating Per Function In Amps
50.0 2nd radio interference
-
Body Height
5.000 inches nominal
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Unpackaged Unit Weight
145.000 pounds
-
Operating Current Rating Per Function In Amps
50.0 3rd radio interference
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Body Length
37.000 inches nominal
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Special Features
three filtered functions
-
Maximum Dielectric Withstanding Dc Voltage
1.2 kilovolts at sea level
-
Operating Voltage Rating And Type Per Function
277.0 volts ac 1st radio interference 1st function and 600.0 volts dc 1st radio interference 1st function
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
25.000 inches nominal
-
Mounting Facility Type And Quantity
4 unthreaded hole
-
Principal Circuitry Type Per Function
inductance-capacitance 3rd radio interference
-
Body Width
20.000 inches nominal
-
Unthreaded Mounting Hole Diameter
0.688 inches nominal
-
Power Line Frequency Rating Per Function In Hertz
60.0 1st radio interference
-
Operating Voltage Rating And Type Per Function
277.0 volts ac 2nd radio interference 2nd function and 600.0 volts dc 2nd radio interference 2nd function
-
Features Provided
corrosion resistant
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
22.000 inches nominal
-
Power Line Frequency Rating Per Function In Hertz
60.0 2nd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference