Technical Characteristics

  • Bushing Length

    0.375 inches maximum

  • Body Style

    multipole-single actuator type

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Body Length

    1.500 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Precious Material And Location

    contact surfaces silver

  • Maximum Continuous Load Current Rating Per Pole

    1.6 amperes ac first location

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac third location

  • Frequency In Hertz

    400.0 all locations

  • Thread Series Designator

    unef

  • Body Width

    1.875 inches maximum

  • Terminal Type And Quantity

    6 wire hook

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations

  • Precious Material

    silver

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Actuator Function

    trip-reset

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant and hermetically sealed

  • Internal Trip Release Configuration

    series trip all locations

  • Thread Pitch Diameters

    +0.3503/+0.3537 inches

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Unpackaged Unit Weight

    4.500 ounces

  • Actuator Position Designation

    at pole two

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Fragility Factor

    moderately rugged

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    130.0 all locations

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Continuous Load Current Rating Per Pole

    0.25 milliamperes ac second location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.000 minimum at 200 pct all locations and 5.000 maximum at 200 pct all locations

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...