972.55.18.512

Circuit Breakers

CIRCUIT BREAKER

972.55.18.512

5925-00-929-7716

5925 - Circuit Breakers

Pilatus Aircraft Ltd

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Test Data Document

    81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • ~1

    data on certain environmental and performance

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Width

    0.580 inches maximum

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Trip Release Characteristic

    time delay single location

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location and 28.0 dc single location

  • Internal Trip Release Configuration

    series trip single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location

  • Case Material

    metal

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 push-pull

  • Trip Release Method

    thermal single location

  • Bushing Length

    0.359 inches nominal

  • Circuit Protection Type

    overcurrent single location

  • Inclosure Protection Type For Which Designed

    vibration resistant and shock resistant

  • Nominal Thread Size

    0.438 inches

  • Thread Quantity Per Inch

    32

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Reset Method

    manual

  • Unpackaged Unit Weight

    0.066 pounds

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.420 inches maximum

  • Thread Series Designator

    uns

  • Center To Center Distance Between Terminals Parallel To Length

    0.593 inches nominal

  • Terminal Type And Quantity

    2 tab w/screw

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    100.0 ac single location and 100.0 dc single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Body Length

    0.780 inches maximum

  • Body Style

    single pole type

  • Frequency In Hertz

    400.0 single location

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac single location and 1.0 amperes dc single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...