13207E2942FN31

Circuit Breakers

CIRCUIT BREAKER

13207E2942FN31

5925-00-929-7719

5925 - Circuit Breakers

Cecom Lr Center

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Test Data Document

    58536-aa55571 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Fragility Factor

    moderately rugged

  • Thread Series Designator

    unc

  • ~1

    data on certain environmental and performance re

  • Terminal Type And Quantity

    2 tab w/screw

  • Overall Length

    2.190 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    0.780 inches nominal

  • Reset Method

    automatic

  • Case Material

    plastic

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant and salt spray proof and fungus resistant

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Body Style

    single pole type

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Trip Release Characteristic

    time delay single location

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    575.0 dc single location

  • Pole Quantity

    1

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes dc single location

  • Trip Release Method

    thermal single location

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Mounting Surface To Terminal End Distance

    1.430 inches maximum

  • Specification/Standard Data

    58536-aa55571/5 government specification

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Body Width

    0.750 inches nominal

  • Storage Type

    general purpose warehouse

  • Trip Delay Time In Seconds Per Rated Continuous Current

    8.000 minimum at 200 pct single location and 50.000 maximum at 200 pct single location

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.812 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...