MIL-C-13516/5
Circuit Breakers
CIRCUIT BREAKER
MIL-C-13516/5
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Width
0.750 inches nominal
-
Fragility Factor
moderately rugged
-
Pole Quantity
1
-
Storage Type
general purpose warehouse
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
25.0 amperes dc single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
575.0 dc single location
-
Internal Trip Release Configuration
series trip single location
-
Nominal Thread Size
0.138 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
8.000 minimum at 200 pct single location and 50.000 maximum at 200 pct
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
Thread Series Designator
unc
-
Terminal Type And Quantity
2 tab w/screw
-
Specification/Standard Data
81349-m13516/5bii government specification
-
Body Style
14a single pole type
-
Overall Length
2.190 inches nominal
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Length
0.780 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.812 inches nominal
-
Mounting Surface To Terminal End Distance
1.430 inches maximum
-
Mounting Facility Type And Quantity
2 threaded hole
-
Operating Voltage Type And Rating Per Pole In Volts
28.0 dc single location
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
thermal single location
-
Trip Release Characteristic
time delay single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
-
Reset Method
automatic
-
Inclosure Protection Type For Which Designed
vibration resistant and shock resistant and salt spray proof and fungus resistant
-
Test Data Document
81349-mil-c-13516 specification