9995643-2
Circuit Breakers
CIRCUIT BREAKER
9995643-2
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Center To Center Distance Between Terminals Parallel To Length
11.590 inches minimum and 11.650 inches maximum
-
Terminal Type And Quantity
6 threaded stud
-
Storage Type
general purpose warehouse
-
Trip Release Ambient Temp Rating
40.0 deg celsius nominal all locations
-
Actuator Function
trip-reset
-
Switch Terminal Type
wire lead
-
Switch Voltage Rating And Type In Volts
600.0 ac and 125.0 dc
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
2.720 inches minimum and 2.780 inches maximum
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Trip Release Method
thermal-magnetic all locations
-
Actuator Position Designation
at pole two
-
Body Style
multipole-single actuator type
-
Case Material
metal
-
Manual Actuator Type And Quantity
1 toggle
-
Switch Current Rating And Type In Amps
6.0 ac and 0.5 dc
-
Frequency In Hertz
60.0 all locations
-
Main Contact Tripping Mechanism Type
trip free
-
Mounting Facility Type And Quantity
4 unthreaded hole
-
Unthreaded Mounting Hole Diameter
0.340 inches minimum and 0.400 inches maximum
-
Arc Quenching Method
magnetic blowout
-
Adjustable Trip Setting Current Range Per Pole In Amps
+2100.0/+7000.0 ac all locations and +2100.0/+7000.0 dc all locations
-
Center To Center Distance Between Terminals Parallel To Width
2.720 inches minimum and 2.780 inches maximum
-
Mounting Surface To Terminal End Distance
10.970 inches minimum and 11.030 inches maximum
-
Inclosure Protection Type For Which Designed
hermetically sealed and weatherproof
-
Switch Contact Arrangement
double pole, double throw
-
Auxiliary Switch Function And Quantity
1 control
-
Body Width
8.220 inches minimum and 8.280 inches maximum
-
Fragility Factor
moderately rugged
-
Trip Release Characteristic
instantaneous all locations
-
Special Handling Feature
magnetic
-
Body Length
15.470 inches minimum and 15.530 inches maximum
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
25000.0 ac all locations and 65000.0 dc all locations
-
Precious Material And Location
contacts silver
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
14.220 inches minimum and 14.280 inches maximum
-
Reset Method
manual
-
Features Provided
adjustable trip release
-
Maximum Continuous Load Current Rating Per Pole
700.0 amperes ac all locations and 700.0 amperes dc all locations
-
Switch Location And Position Designation
internal at pole three
-
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations and 125.0 dc all locations
-
Boss Height
0.350 inches minimum and 0.410 inches maximum
-
Precious Material
silver