9995643-2

Circuit Breakers

CIRCUIT BREAKER

9995643-2

5925-00-930-2265

5925 - Circuit Breakers

General Electric Co

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Length

    11.590 inches minimum and 11.650 inches maximum

  • Terminal Type And Quantity

    6 threaded stud

  • Storage Type

    general purpose warehouse

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Actuator Function

    trip-reset

  • Switch Terminal Type

    wire lead

  • Switch Voltage Rating And Type In Volts

    600.0 ac and 125.0 dc

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    2.720 inches minimum and 2.780 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Actuator Position Designation

    at pole two

  • Body Style

    multipole-single actuator type

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Switch Current Rating And Type In Amps

    6.0 ac and 0.5 dc

  • Frequency In Hertz

    60.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Unthreaded Mounting Hole Diameter

    0.340 inches minimum and 0.400 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Adjustable Trip Setting Current Range Per Pole In Amps

    +2100.0/+7000.0 ac all locations and +2100.0/+7000.0 dc all locations

  • Center To Center Distance Between Terminals Parallel To Width

    2.720 inches minimum and 2.780 inches maximum

  • Mounting Surface To Terminal End Distance

    10.970 inches minimum and 11.030 inches maximum

  • Inclosure Protection Type For Which Designed

    hermetically sealed and weatherproof

  • Switch Contact Arrangement

    double pole, double throw

  • Auxiliary Switch Function And Quantity

    1 control

  • Body Width

    8.220 inches minimum and 8.280 inches maximum

  • Fragility Factor

    moderately rugged

  • Trip Release Characteristic

    instantaneous all locations

  • Special Handling Feature

    magnetic

  • Body Length

    15.470 inches minimum and 15.530 inches maximum

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    25000.0 ac all locations and 65000.0 dc all locations

  • Precious Material And Location

    contacts silver

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    14.220 inches minimum and 14.280 inches maximum

  • Reset Method

    manual

  • Features Provided

    adjustable trip release

  • Maximum Continuous Load Current Rating Per Pole

    700.0 amperes ac all locations and 700.0 amperes dc all locations

  • Switch Location And Position Designation

    internal at pole three

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations and 125.0 dc all locations

  • Boss Height

    0.350 inches minimum and 0.410 inches maximum

  • Precious Material

    silver

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...