AM17-10-32VDC55

Circuit Breakers

CIRCUIT BREAKER

AM17-10-32VDC55

5925-00-931-5940

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Width

    0.750 inches nominal

  • Internal Trip Release Configuration

    series trip single location

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes dc single location

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.812 inches nominal

  • Circuit Protection Type

    overcurrent single location

  • Inclosure Protection Type For Which Designed

    explosion resistant

  • Trip Release Characteristic

    time delay single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.400 minimum at 200 pct and 7.500 maximum at 200 pct single location

  • Iii Arc Quenching Method

    magnetic blowout

  • Actuator Function

    trip-reset

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3000.0 dc single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Terminal Type And Quantity

    2 screw

  • Reset Method

    manual

  • Trip Release Method

    magnetic-hydraulic single location

  • Iii Special Handling Feature

    magnetic

  • Iii Fragility Factor

    moderately rugged

  • Body Style

    single pole type

  • Mounting Surface To Terminal End Distance

    2.000 inches nominal

  • Thread Series Designator

    unc

  • Case Material

    plastic

  • Main Contact Tripping Mechanism Type

    trip free

  • Thread Quantity Per Inch

    32

  • Iii Storage Type

    general purpose warehouse

  • Nominal Thread Size

    0.138 inches

  • Pole Quantity

    1

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Operating Voltage Type And Rating Per Pole In Volts

    32.0 dc single location

  • Body Length

    2.500 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.190 inches nominal

  • Actuator Position Designation

    at pole one

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...