DN022
Coils and Transformers
TRANSFORMER,POWER
DN022
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Width
2.250 inches maximum
-
Mounting Facility Quantity
4 single group
-
Transformer Winding Connection Type
wye-wye
-
Winding Operating Voltage
208.00 ac volts maximum single component single primary
-
Body Height
3.000 inches maximum
-
Winding Shielding Method
internal shield grounded to inclosure and core single component
-
Center To Center Distance Between Mounting Facilities Parallel To Length
3.312 inches nominal single mounting facility single center group
-
Winding Tap Location (Non-Core)
err-070
-
Mounting Method
threaded stud single group
-
Thread Quantity Per Inch
32 single group
-
Winding Operating Current
1.0 amperes dc maximum single component all secondary
-
Winding Function And Quantity
1 primary single component and 2 secondary single component
-
Thread Series Designator
unf single group
-
Input-Output Phase Relationship
three phase to three phase single component
-
Body Length
4.250 inches maximum
-
Reliability Indicator
not established
-
Frequency Rating
400.0 hertz nominal single component
-
Thread Class (Non-Core)
err-070
-
Inclosure Type
hermetically sealed
-
Nominal Thread Size
0.190 inches single group
-
Terminal Type And Quantity
10 tab, solder lug
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.312 inches nominal single mounting facility single center group
-
Winding Operating Voltage
32.00 ac volts nominal single component all secondary