434254-175
Circuit Breakers
CIRCUIT BREAKER
434254-175
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Trip Release Method
magnetic single location
-
Thread Series Designator
unc
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 ac single location
-
Reset Method
manual
-
Center To Center Distance Between Terminals Parallel To Length
2.740 inches minimum and 2.760 inches maximum
-
Boss Height
0.115 inches minimum and 0.135 inches maximum
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Body Width
1.459 inches minimum and 1.479 inches maximum
-
Terminal Type And Quantity
2 screw
-
Ultimate Trip Time Per Pole In Seconds
0.550 minimum single location and 1.800 maximum single location
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.302 inches minimum and 1.322 inches maximum
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location
-
Body Height
2.646 inches minimum and 2.667 inches maximum
-
Inclosure Protection Type For Which Designed
fungus resistant
-
Pole Quantity
1
-
Manual Actuator Type And Quantity
1 toggle
-
Internal Trip Release Configuration
series trip single location
-
Nominal Thread Size
0.138 inches
-
Trip Release Characteristic
time delay single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Body Style
single pole type
-
Body Length
3.209 inches minimum and 3.229 inches maximum
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.250 minimum at 200 pct single location and 1.000 maximum at 200 pct single location
-
Frequency In Hertz
60.0 single location
-
Mounting Slot Width
0.164 inches nominal
-
Maximum Continuous Load Current Rating Per Pole
17.5 amperes ac single location
-
Case Material
plastic
-
Mounting Facility Type And Quantity
2 threaded bushing w/panel seal