434254-175

Circuit Breakers

CIRCUIT BREAKER

434254-175

5925-00-932-3027

5925 - Circuit Breakers

Carleton Life Support Systems Inc.

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

  • Thread Series Designator

    unc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1500.0 ac single location

  • Reset Method

    manual

  • Center To Center Distance Between Terminals Parallel To Length

    2.740 inches minimum and 2.760 inches maximum

  • Boss Height

    0.115 inches minimum and 0.135 inches maximum

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Body Width

    1.459 inches minimum and 1.479 inches maximum

  • Terminal Type And Quantity

    2 screw

  • Ultimate Trip Time Per Pole In Seconds

    0.550 minimum single location and 1.800 maximum single location

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.302 inches minimum and 1.322 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Body Height

    2.646 inches minimum and 2.667 inches maximum

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Body Style

    single pole type

  • Body Length

    3.209 inches minimum and 3.229 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.250 minimum at 200 pct single location and 1.000 maximum at 200 pct single location

  • Frequency In Hertz

    60.0 single location

  • Mounting Slot Width

    0.164 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    17.5 amperes ac single location

  • Case Material

    plastic

  • Mounting Facility Type And Quantity

    2 threaded bushing w/panel seal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...