X0411-50-240VAC60C9

Circuit Breakers

CIRCUIT BREAKER

X0411-50-240VAC60C9

5925-00-932-6807

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.740 inches minimum and 2.760 inches maximum

  • Inclosure Protection Type For Which Designed

    general purpose

  • Terminal Type And Quantity

    2 bus bar

  • Body Style

    single pole type

  • Trip Release Method

    magnetic-hydraulic single location

  • Frequency In Hertz

    60.0 single location

  • Unpackaged Unit Weight

    11.000 ounces

  • Center To Center Distance Between Terminals Parallel To Length

    4.370 inches minimum and 4.390 inches maximum

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac single location

  • Special Handling Feature

    magnetic

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Trip Delay Time In Seconds Per Rated Continuous Current

    39.000 minimum at 200 pct single location and 105.000 maximum at 200 pct single location

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Body Height

    2.820 inches minimum and 2.840 inches maximum

  • Body Width

    1.020 inches minimum and 1.040 inches maximum

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Body Length

    4.740 inches minimum and 4.760 inches maximum

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...