M39019-1-29
Circuit Breakers
CIRCUIT BREAKER
M39019-1-29
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Test Data Document
81349-mil-c-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Trip Release Method
magnetic single location
-
Terminal Type And Quantity
2 wire hook
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac single location
-
Reset Method
manual
-
Ultimate Trip Time Per Pole In Seconds
0.200 minimum single location and 7.000 maximum single location
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Actuator Position Designation
at pole one
-
Actuator Function
trip-reset
-
Inclosure Protection Type For Which Designed
fungus resistant and hermetically sealed
-
Nominal Thread Size
0.375 inches
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Pole Quantity
1
-
Case Material
metal
-
Manual Actuator Type And Quantity
1 toggle
-
Internal Trip Release Configuration
series trip single location
-
Trip Release Characteristic
time delay single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Main Contact Tripping Mechanism Type
trip free
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac single location
-
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac single location
-
Body Length
1.562 inches maximum
-
Frequency In Hertz
400.0 single location
-
Center To Center Distance Between Terminals Parallel To Length
0.906 inches maximum
-
Body Style
single pole type
-
Body Width
0.625 inches maximum
-
Thread Series Designator
unef
-
Mounting Surface To Terminal End Distance
1.700 inches maximum
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.950 maximum at 200 pct single location and 0.055 minimum at 200 pct single location and 0.240 maximum at 400 pct single location
-
Bushing Length
0.380 inches maximum
-
~1
data on certain environmental and performanc