Technical Characteristics
-
Vibration Resistance Range In Hertz
+10.0/+2000.0
-
Mounting Facility Type And Quantity
2 threaded hole
-
Source Impedance Rating Per Function
50.0 ohms 5th radio interference
-
Functional Terminal Type And Quantity
23 turret input 1st function
-
Operating Current Rating Per Function In Amps
0.025 3rd radio interference
-
Operating Voltage Rating And Type Per Function
25.0 volts dc 3rd radio interference 3rd function
-
Operating Current Rating Per Function In Amps
0.025 4th radio interference
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Operating Voltage Rating And Type Per Function
25.0 volts dc 4th radio interference 4th function
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Operating Current Rating Per Function In Amps
0.025 5th radio interference
-
Source Impedance Rating Per Function
50.0 ohms 6th radio interference
-
Functional Terminal Type And Quantity
23 turret output 2nd function
-
Operating Current Rating Per Function In Amps
0.025 6th radio interference
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Operating Voltage Rating And Type Per Function
25.0 volts dc 5th radio interference 5th function
-
Body Length
3.000 inches nominal
-
Operating Voltage Rating And Type Per Function
200.0 volts ac 2nd radio interference 2nd function
-
Body Width
5.000 inches nominal
-
Load Impedance Per Function
50.0 ohms 4th radio interference
-
Operating Voltage Rating And Type Per Function
50.0 volts dc 6th radio interference 6th function
-
Maximum Voltage Drop Per Function
100.0 millivolts dc 3rd radio interference
-
Maximum Voltage Drop Per Function
100.0 millivolts dc 4th radio interference
-
Maximum Voltage Drop Per Function
1.0 volts ac 1st radio interference
-
Maximum Voltage Drop Per Function
100.0 millivolts dc 5th radio interference
-
Maximum Voltage Drop Per Function
100.0 millivolts dc 6th radio interference
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Functional Terminal Type And Quantity
1 tab, solder lug ground 3rd function
-
Load Impedance Per Function
50.0 ohms 5th radio interference
-
Special Features
23 functions
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
4.460 inches nominal
-
Mounting Facility Type And Quantity
3 threaded stud
-
Load Impedance Per Function
50.0 ohms 6th radio interference
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Maximum Voltage Drop Per Function
1.0 volts ac 2nd radio interference
-
Operating Current Rating Per Function In Amps
0.7 1st radio interference
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 1st radio interference
-
Operating Current Rating Per Function In Amps
0.7 2nd radio interference
-
Inclosure Type
encased
-
Power Line Frequency Rating Per Function In Hertz
400.0 2nd radio interference
-
Body Height
1.547 inches nominal
-
Overall Length
3.975 inches nominal
-
Source Impedance Rating Per Function
50.0 ohms 4th radio interference
-
Operating Temp Range
-55.0/+105.0 deg celsius
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Operating Voltage Rating And Type Per Function
200.0 volts ac 1st radio interference 1st function