1945824-13

Circuit Breakers

CIRCUIT BREAKER

1945824-13

5925-00-934-2648

5925 - Circuit Breakers

Honeywell Intl Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Circuit Protection Type

    overcurrent single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Pole Quantity

    1

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Maximum Continuous Load Current Rating Per Pole

    1.5 amperes ac single location and 1.5 amperes dc single location

  • Body Length

    1.500 inches maximum

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 single location

  • Frequency In Hertz

    400.0 single location

  • Inclosure Protection Type For Which Designed

    vibrationproof and shockproof and hermetically sealed

  • Body Style

    single pole type

  • Test Data Document

    19315-1945824 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

  • Body Width

    0.625 inches maximum

  • Mounting Surface To Terminal End Distance

    1.605 inches maximum

  • Thread Series Designator

    unef

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location and 50.0 dc single location

  • Bushing Length

    0.380 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.090 minimum at 200 pct single location and 0.600 maximum at 200 pct single location

  • Trip Release Method

    magnetic single location

  • Terminal Type And Quantity

    2 wire hook

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location and 1000.0 dc single location

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Thread Pitch Diameters

    +0.3503/+0.3537 inches

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...