MS26574-7-1/2A

Circuit Breakers

CIRCUIT BREAKER

MS26574-7-1/2A

5925-00-935-5287

5925 - Circuit Breakers

Military Standards

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 28.0 dc single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Body Length

    0.780 inches maximum

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 30.0 dc

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location and 2500.0 dc single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Switch Current Rating And Type In Amps

    3.0 ac and 5.0 dc

  • Thread Series Designator

    un

  • Center To Center Distance Between Terminals Parallel To Length

    0.593 inches nominal

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant and sand resistant and corrosion resistant and dustproof and explosion resistant and vibration resistant

  • Fragility Factor

    moderately rugged

  • Unpackaged Unit Weight

    0.066 pounds

  • Switch Terminal Type

    tab, solder lug

  • Body Width

    0.539 inches nominal

  • Bushing Length

    0.250 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    7.5 amperes ac single location and 7.5 amperes dc single location

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Mounting Surface To Terminal End Distance

    1.525 inches maximum

  • Actuator Function

    trip-reset

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.438 inches

  • Specification/Standard Data

    81349-mil-c-5809 government specification

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Test Data Document

    96906-ms26574 standard (includes industry or association standards, individual manufactureer standards, etc.).

  • Switch Contact Arrangement

    single pole, double throw

  • Pole Quantity

    1

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location

  • Internal Trip Release Configuration

    series trip single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...