Technical Characteristics
-
Operating Temp Rating
-65.0 deg fahrenheit minimum and 250.0 deg fahrenheit maximum
-
Mounting Method
bracket and unthreaded hole
-
Terminal Type
connector, receptacle
-
Media For Which Designed
liquid
-
Contact Stimulus Rating
10.00 deactuation point minimum pounds per square inch gage and 97.00 actuation point nominal pounds per square inch gage and 103.00 actuation point minimum pounds per square inch gage and 13.00 deactuation point maximum pounds per square inch gage
-
Contact Voltage Rating In Volts
30.0 dc at sea level single voltage
-
Contact Adjustability
actuation point not adjustable and deactuation point not adjustable
-
Overall Length
3.750 inches maximum
-
Proof Pressure
200.00 pounds per square inch gage
-
Distance Between Mounting Facility Centers
0.500 inches nominal
-
Thread Series Designator
unjf single pressure connection
-
Style Designator
rectangular
-
Thread Class
3a single pressure connection
-
Overall Diameter
2.250 inches maximum
-
Nonpile-Up Contact Arrangement
1 pole, double throw, one position momentary
-
Pressure Connector Type
flared, threaded external single connection
-
Nominal Thread Size
0.438 inches single pressure connection
-
Unthreaded Mounting Hole Diameter
0.204 inches nominal
-
Pressure Switch Type
gage
-
Outside Diameter
0.438 inches nominal single connection
-
Mounting Facility Pattern
two position in-line
-
Contact Action Stimulus
increase