MIL-C-13516/3

Circuit Breakers

CIRCUIT BREAKER

MIL-C-13516/3

5925-00-937-4574

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    18a single pole type

  • Center To Center Distance Between Terminals Parallel To Length

    1.485 inches minimum and 1.515 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.500 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.000 inches nominal

  • Mounting Surface To Terminal End Distance

    2.158 inches nominal

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    575.0 dc single location

  • Trip Release Method

    thermal single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Reset Method

    manual

  • Internal Trip Release Configuration

    series trip single location

  • Inclosure Protection Type For Which Designed

    vibration resistant and shock resistant and salt spray proof and fungus resistant

  • Overall Length

    4.000 inches nominal

  • Body Width

    2.120 inches nominal

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    1

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    200.0 amperes dc single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 push button

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Nominal Thread Size

    0.190 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    8.000 minimum at 200 pct single location and 50.000 maximum at 200 pct

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Special Features

    this item is nonwaterproof

  • Test Data Document

    81349-mil-c-13516 specification

  • Thread Series Designator

    unf

  • Terminal Type And Quantity

    2 threaded stud

  • Specification/Standard Data

    81349-m13516/3bi government specification

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...