AMIR-B2-AC07D-A52-1R72

Circuit Breakers

CIRCUIT BREAKER

AMIR-B2-AC07D-A52-1R72

5925-00-938-7370

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Mounting Surface To Terminal End Distance

    3.239 inches nominal

  • Storage Type

    general purpose warehouse

  • Switch Current Rating And Type In Amps

    5.0 ac and 1.0 dc

  • Actuator Function

    trip-reset

  • Switch Voltage Rating And Type In Volts

    125.0 ac and 50.0 dc

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Ultimate Trip Time Per Pole In Seconds

    5.000 minimum single location and 20.000 maximum single location

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Body Width

    0.990 inches nominal

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Body Length

    3.719 inches nominal

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Boss Height

    0.156 inches nominal

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc single location

  • Body Style

    single pole type

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.850 minimum at 200 pct single location and 2.500 maximum at 200 pct single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Inclosure Protection Type For Which Designed

    fungus resistant and explosion resistant and moisture resistant

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    4000.0 dc single location

  • Maximum Continuous Load Current Rating Per Pole

    1.7 amperes dc single location

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Switch Terminal Type

    tab w/screw

  • Terminal Type And Quantity

    2 threaded stud

  • Center To Center Distance Between Terminals Parallel To Length

    3.063 inches nominal

  • Switch Contact Arrangement

    single pole, double throw

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...