MIL-DTL-27715
Circuit Breakers
CIRCUIT BREAKER
MIL-DTL-27715
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Manual Actuator Type And Quantity
1 push button
-
Mounting Surface To Terminal End Distance
2.370 inches nominal
-
Mounting Facility Type And Quantity
2 threaded hole
-
Specification/Standard Data
96906-ms24571 government standard
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Inclosure Protection Type For Which Designed
shock resistant and sandtight and vaportight and salt spray proof and explosion proof and humidity proof and dusttight and fungus proof
-
Unpackaged Unit Weight
0.200 pounds
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.800 inches minimum and 1.820 inches maximum
-
Pole Quantity
1
-
Body Length
2.189 inches maximum
-
Internal Trip Release Configuration
series trip single location
-
Nominal Thread Size
0.138 inches
-
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac single location and 28.0 dc single location
-
Center To Center Distance Between Terminals Parallel To Length
1.190 inches nominal
-
Trip Release Characteristic
time delay single location
-
Bushing Length
0.187 inches minimum and 0.249 inches maximum
-
Main Contact Tripping Mechanism Type
trip free
-
Frequency In Hertz
400.0 single location
-
Body Style
single pole type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
-
Terminal Type And Quantity
2 tab w/screw
-
Fragility Factor
moderately rugged
-
Trip Release Method
magnetic single location
-
Special Handling Feature
magnetic
-
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac single location and 50.0 amperes dc single location
-
Thread Series Designator
unc
-
Reset Method
manual
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Body Width
0.760 inches maximum
-
~1
data on certain environmental and performanc
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac single location and 5000.0 dc single location
-
Trip Delay Time In Seconds Per Rated Continuous Current
28.000 minimum at 200 pct single location and 55.000 maximum at 200 pct single location
-
Case Material
plastic
-
Test Data Document
81349-mil-c-27715 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type