1901-003-25
Circuit Breakers
CIRCUIT BREAKER
1901-003-25
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
~1
data on certain environmental and performanc
-
Unpackaged Unit Weight
0.200 pounds
-
Manual Actuator Type And Quantity
1 push-pull
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.800 inches minimum and 1.820 inches maximum
-
Pole Quantity
1
-
Case Material
metal
-
Body Length
2.189 inches maximum
-
Nominal Thread Size
0.138 inches
-
Operating Voltage Type And Rating Per Pole In Volts
200.0 ac single location and 28.0 dc single location
-
Trip Release Characteristic
time delay single location
-
Bushing Length
0.187 inches minimum and 0.249 inches maximum
-
Main Contact Tripping Mechanism Type
trip free
-
Trip Delay Time In Seconds Per Rated Continuous Current
24.000 minimum at 200 pct single location and 50.000 maximum at 200 pct single location
-
Frequency In Hertz
400.0 single location
-
Body Style
single pole type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
-
Terminal Type And Quantity
2 tab w/screw
-
Inclosure Protection Type For Which Designed
hermetically sealed and explosion proof and humidity resistant and vibrationproof and dustproof and shock resistant and salt spray proof and sand resistant and corrosion resistant and fungus resistant
-
Fragility Factor
moderately rugged
-
Trip Release Method
magnetic single location
-
Special Handling Feature
magnetic
-
Thread Series Designator
unc
-
Reset Method
manual
-
Internal Trip Release Configuration
relay trip single location
-
Actuator Position Designation
at pole one
-
Maximum Continuous Load Current Rating Per Pole
25.0 amperes ac single location and 25.0 amperes dc single location
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Body Width
0.760 inches maximum
-
Mounting Surface To Terminal End Distance
2.370 inches nominal
-
Mounting Facility Type And Quantity
2 threaded hole
-
Specification/Standard Data
96906-ms24571 government standard
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac single location and 5000.0 dc single location
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Center To Center Distance Between Terminals Parallel To Length
1.190 inches maximum
-
Test Data Document
81349-mil-c-27715 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type