FJ3-M150

Circuit Breakers

CIRCUIT BREAKER

FJ3-M150

5925-00-942-4010

5925 - Circuit Breakers

Spd Electrical Systems Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Inclosure Protection Type For Which Designed

    general purpose

  • Maximum Continuous Load Current Rating Per Pole

    150.0 amperes ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    14000.0 ac all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    110.000 nominal at 200 pct all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations

  • Case Material

    plastic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Features Provided

    adjustable trip release

  • Center To Center Distance Between Terminals Parallel To Width

    1.500 inches nominal

  • Adjustable Trip Setting Current Range Per Pole In Amps

    +750.0/+1600.0 ac all locations

  • Storage Type

    general purpose warehouse

  • Center To Center Distance Between Terminals Parallel To Length

    8.750 inches nominal

  • Actuator Function

    trip-reset

  • Body Width

    4.500 inches nominal

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Body Length

    10.000 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.250 inches nominal

  • Trip Release Method

    thermal-magnetic all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.875 inches nominal

  • Actuator Position Designation

    at pole two

  • Trip Release Ambient Temp Rating

    50.0 deg celsius nominal all locations

  • Body Style

    multipole-single actuator type

  • Boss Height

    0.250 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    8.625 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Terminal Type And Quantity

    6 compression

  • Mounting Surface To Terminal End Distance

    4.062 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...