501I202R

Circuit Breakers

CIRCUIT BREAKER

501I202R

5925-00-942-4045

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Internal Trip Release Configuration

    series trip

  • Switch Location And Position Designation

    external at pole one

  • Inclosure Protection Type For Which Designed

    shockproof and vibrationproof and hermetically sealed

  • Switch Current Rating And Type In Amps

    1.0 ac and 0.5 dc

  • Test Data Document

    10001-2282221 drawing

  • Thread Series Designator

    unef

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes dc

  • Ultimate Trip Time Per Pole In Seconds

    0.035 nominal

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Nominal Thread Size

    0.375 inches

  • Switch Terminal Type

    eyelet

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 50.0 dc

  • Terminal Type And Quantity

    2 wire hook

  • Thread Quantity Per Inch

    32

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Mounting Surface To Terminal End Distance

    1.635 inches nominal

  • Case Material

    metal

  • Body Width

    0.625 inches maximum

  • Body Length

    1.750 inches maximum

  • Trip Release Characteristic

    instantaneous

  • Trip Release Method

    magnetic

  • Circuit Protection Type

    overcurrent

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc

  • Pole Quantity

    1

  • Switch Contact Arrangement

    single pole,double throw

  • Center To Center Distance Between Terminals Parallel To Length

    0.687 inches nominal

  • Bushing Length

    0.315 inches nominal

  • Body Style

    single pole type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...