Technical Characteristics
-
Center To Center Distance Between Terminals Parallel To Width
0.620 inches minimum and 0.630 inches maximum
-
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac all locations
-
Fragility Factor
moderately rugged
-
Switch Terminal Type
tab, solder lug
-
Circuit Protection Type
overcurrent all locations
-
Pole Quantity
2
-
Reset Method
manual
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Storage Type
general purpose warehouse
-
Switch Voltage Rating And Type In Volts
50.0 dc
-
Switch Location And Position Designation
internal at pole two
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Body Width
1.212 inches minimum and 1.274 inches maximum
-
Internal Trip Release Configuration
series trip all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Switch Current Rating And Type In Amps
5.0 dc
-
Nominal Thread Size
0.375 inches
-
Thread Quantity Per Inch
32
-
Body Length
1.448 inches minimum and 1.510 inches maximum
-
Trip Release Method
magnetic all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Inclosure Protection Type For Which Designed
hermetically sealed
-
Terminal Type And Quantity
4 wire hook
-
Bushing Length
0.360 inches minimum and 0.380 inches maximum
-
Switch Contact Arrangement
single pole, double throw
-
Body Style
multipole-single actuator type
-
Case Material
metal
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.030 minimum at 200 pct all locations and 0.900 maximum at 200 pct all locations
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Position Designation
between pole one and two
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Mounting Surface To Terminal End Distance
1.647 inches minimum and 1.709 inches maximum
-
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac all locations
-
Frequency In Hertz
400.0 all locations
-
Thread Series Designator
unef
-
Auxiliary Switch Function And Quantity
1 alarm
-
Center To Center Distance Between Terminals Parallel To Length
0.870 inches minimum and 0.880 inches maximum