AM12HK10-32VDC5

Circuit Breakers

CIRCUIT BREAKER

AM12HK10-32VDC5

5925-00-944-3848

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Switch Terminal Type

    tab, solder lug

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Mounting Surface To Terminal End Distance

    2.461 inches minimum and 2.481 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes dc single location

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Circuit Protection Type

    overcurrent single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 200 pct single location and 0.550 maximum at 200 pct single location

  • Terminal Type And Quantity

    2 threaded stud

  • Case Material

    plastic

  • Switch Location And Position Designation

    internal at pole one

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    32.0 dc single location

  • Body Length

    2.490 inches minimum and 2.510 inches maximum

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Unpackaged Unit Weight

    4.250 ounces

  • Trip Release Method

    magnetic-hydraulic single location

  • Body Style

    single pole type

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Inclosure Protection Type For Which Designed

    general purpose

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3000.0 dc single location

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Trip Release Characteristic

    time delay single location

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Pole Quantity

    1

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Switch Current Rating And Type In Amps

    2.5 ac and 1.0 dc

  • Switch Contact Arrangement

    single pole, double throw

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...