172059-000
Coils and Transformers
TRANSFORMER,POWER
172059-000
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Operating Current
4.0 amperes ac nominal single component 2nd secondary
-
Mounting Facility Quantity
4 4th group
-
Transformer Winding Connection Type
delta-wye
-
Thread Direction (Non-Core)
err-070
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.234 inches minimum single mounting facility 2nd center group and 2.266 inches maximum single mounting facility 2nd center group
-
Body Width
2.734 inches minimum and 2.766 inches maximum
-
Distance Between Mounting Facility Centers
2.234 inches minimum single mounting facility 1st center group and 2.266 inches maximum single mounting facility 1st center group
-
Nominal Thread Size
0.112 inches 2nd group
-
Mounting Facility Quantity
2 1st group
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.734 inches minimum single mounting facility 2nd center group and 2.766 inches maximum single mounting facility 2nd center group
-
Nominal Thread Size
0.112 inches 3rd group
-
Mounting Facility Quantity
4 2nd group
-
Nominal Thread Size
0.164 inches 4th group
-
Mounting Facility Quantity
4 3rd group
-
Winding Operating Voltage
39.20 ac volts nominal single component 1st secondary
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.734 inches minimum single mounting facility 3rd center group and 2.766 inches maximum single mounting facility 3rd center group
-
Body Length
3.609 inches minimum and 3.641 inches maximum
-
Winding Power Rating
29.13 volts-amperes single component 1st secondary
-
Thread Series Designator
unc all groupings
-
Input-Output Phase Relationship
three phase to single phase single component and three phase to three phase single component
-
Maximum Operating Temp
170.0 deg celsius
-
Winding Tap Location (Non-Core)
err-070
-
Winding Power Rating
26.0 volts-amperes single component 2nd secondary
-
Overall Height
1.922 inches minimum and 1.954 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.234 inches minimum single mounting facility 3rd center group and 2.266 inches maximum single mounting facility 3rd center group
-
Winding Function And Quantity
1 primary single component and 2 secondary single component
-
Inclosure Type
fully inclosed
-
Winding Operating Voltage
198.90 ac volts nominal single component single primary
-
Mounting Method
threaded hole all groupings
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.052 inches minimum single mounting facility 4th center group and 1.072 inches maximum single mounting facility 4th center group
-
Winding Shielding Method
internal shield brought out to terminal single component
-
Terminal Type And Quantity
13 turret
-
Nominal Thread Size
0.138 inches 1st group
-
Winding Operating Voltage
6.50 ac volts nominal single component 2nd secondary
-
Winding Operating Current
743.0 milliamperes ac nominal single component 1st secondary
-
Reliability Indicator
not established
-
Frequency Rating
400.0 hertz nominal single component
-
Test Data Document
04660-73c828 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.115 inches minimum single mounting facility 4th center group and 2.135 inches maximum single mounting facility 4th center group