Q531487058

Circuit Breakers

CIRCUIT BREAKER

Q531487058

5925-00-946-7779

5925 - Circuit Breakers

Rheinmetall Air Defence Ag

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Pole Quantity

    1

  • Mounting Surface To Terminal End Distance

    1.287 inches minimum and 1.317 inches maximum

  • Unpackaged Unit Weight

    30.0 grams

  • Manual Actuator Type And Quantity

    1 push-pull

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Arc Quenching Method

    air

  • Trip Release Method

    thermal single location

  • Circuit Protection Type

    overcurrent single location

  • Nominal Thread Size

    0.438 inches

  • Thread Quantity Per Inch

    32

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0 single location

  • Switch Current Rating And Type In Amps

    5.0 dc

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Inclosure Protection Type For Which Designed

    sand resistant and humidity resistant and corrosion resistant and explosion proof and shock resistant and vibration resistant

  • Switch Terminal Type

    tab, solder lug

  • Actuator Function

    reset

  • Case Material

    plastic

  • Thread Series Designator

    uns

  • Center To Center Distance Between Terminals Parallel To Length

    0.562 inches minimum and 0.624 inches maximum

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Terminal Type And Quantity

    2 tab w/screw

  • Body Length

    0.719 inches minimum and 0.781 inches maximum

  • Body Width

    0.531 inches minimum and 0.593 inches maximum

  • Body Style

    single pole type

  • Bushing Length

    0.328 inches minimum and 0.390 inches maximum

  • Switch Voltage Rating And Type In Volts

    28.0 dc

  • Frequency In Hertz

    400.0 single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    800.0 ac single location

  • Switch Contact Arrangement

    single pole, single throw, normally closed

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Trip Release Characteristic

    time delay single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 28.0 dc single location

  • Switch Location And Position Designation

    external at pole one

  • Internal Trip Release Configuration

    series trip single location

  • Special Features

    unlimited dc interrupting capacity

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac single location and 5.0 amperes dc single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...