AP1-35-29

Circuit Breakers

CIRCUIT BREAKER

AP1-35-29

5925-00-947-2959

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac

  • Operating Voltage Type And Rating Per Pole In Volts

    230.0 ac

  • Circuit Protection Type

    overcurrent

  • Trip Release Characteristic

    time delay

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Frequency In Hertz

    60.0

  • Unpackaged Unit Weight

    50.0 grams

  • Terminal Type And Quantity

    2 wire hook

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant and hermetically sealed and salt spray proof

  • Thread Series Designator

    unef

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.700 inches maximum

  • Arc Quenching Method

    air

  • Body Style

    single pole type

  • Bushing Length

    0.332 inches minimum and 0.380 inches maximum

  • Body Length

    1.562 inches maximum

  • Body Width

    0.625 inches maximum

  • Case Material

    metal

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac

  • Trip Release Method

    magnetic

  • Internal Trip Release Configuration

    series trip

  • Nominal Thread Size

    0.375 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.055 minimum at 200 pct and 0.950 maximum at 200 pct

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...