143-1001-40

Resistors

RESISTOR,THERMAL

143-1001-40

5905-00-947-3797

5905 - Resistors

Tabet Manufacturing Company Inc.

RESISTOR,THERMAL

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Zero Power Resistance At Specified Temp

    4.4 kilohms 9th resistance-temperature point

  • Inclosure Type

    encapsulated

  • Unpackaged Unit Weight

    0.009 pounds

  • Resistance Tolerance At A Specified Temp In Percent

    -14.7/+14.7 2nd resistance-temperature point

  • Zero Power Resistance At Specified Temp

    18.4 kilohms 7th resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    70.0 deg celsius 6th resistance-temperature point

  • Resistance Tolerance At A Specified Temp In Percent

    -12.5/+12.5 3rd resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    100.0 deg celsius 7th resistance-temperature point

  • Resistance Tolerance At A Specified Temp In Percent

    -17.6/+17.6 1st resistance-temperature point

  • Thermal Time Constant In Seconds

    45.0

  • Terminal Length

    3.000 inches nominal

  • Zero Power Resistance At Specified Temp

    110.9 kilohms 5th resistance-temperature point

  • Zero Power Resistance At Specified Temp

    8.6 kilohms 8th resistance-temperature point

  • Reliability Indicator

    not established

  • Terminal Type And Quantity

    2 wire lead

  • Ambient Temp At Full Rated Power

    25.0 deg celsius

  • Cubic Measure

    0.094 cubic inches

  • Zero Power Resistance At Specified Temp

    1.4 kilohms 10th resistance-temperature point

  • Zero Power Resistance At Specified Temp

    414.5 kilohms 4th resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    0.0 deg celsius 3rd resistance-temperature point

  • Terminal Diameter

    0.025 inches nominal

  • Resistance Tolerance At A Specified Temp In Percent

    -16.3/+16.3 7th resistance-temperature point

  • Zero Power Resistance At Specified Temp

    12.3 megohms 1st resistance-temperature point

  • Resistance Tolerance At A Specified Temp In Percent

    -21.8/+21.8 10th resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    150.0 deg celsius 9th resistance-temperature point

  • Reference Temp In Deg Celsius

    25.0

  • Zero Power Resistance At Specified Temp

    51.2 kilohms 6th resistance-temperature point

  • Probe Diameter

    0.250 inches nominal

  • Resistance Tolerance At A Specified Temp In Percent

    -10.3/+10.3 4th resistance-temperature point

  • Maximum Operating Temp

    200.0 deg celsius

  • Zero Power Resistance At Specified Temp

    3.366 megohms 2nd resistance-temperature point

  • Style Designator

    probe

  • Temp Points For Resistance Readings At Zero Power

    200.0 deg celsius 10th resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    50.0 deg celsius 5th resistance-temperature point

  • Resistance Tolerance At A Specified Temp In Percent

    -19.3/+19.3 9th resistance-temperature point

  • Zero Power Resistance Tolerance In Percent At Reference Temp

    -5.0/+5.0

  • Resistance Tolerance At A Specified Temp In Percent

    -17.9/+17.9 8th resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    125.0 deg celsius 8th resistance-temperature point

  • Zero Power Resistance At Specified Temp

    1.11 megohms 3rd resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    -20.0 deg celsius 2nd resistance-temperature point

  • Zero Power Resistance

    330.000 kilohms

  • Temp Points For Resistance Readings At Zero Power

    20.0 deg celsius 4th resistance-temperature point

  • Resistance Tolerance At A Specified Temp In Percent

    -14.2/+14.2 6th resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    -40.0 deg celsius 1st resistance-temperature point

  • Probe Length

    2.500 inches nominal

  • Resistance Tolerance At A Specified Temp In Percent

    -12.5/+12.5 5th resistance-temperature point

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...