78-120-2

Circuit Breakers

CIRCUIT BREAKER

78-120-2

5925-00-949-1215

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.000 minimum at 200 pct all locations and hermetically sealed and fungus resistant and moisture resistant

  • Trip Release Method

    magnetic-hydraulic all locations

  • Terminal Type And Quantity

    4 wire hook

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac first location

  • Body Style

    multipole-single actuator type

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    between pole one and two

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Continuous Load Current Rating Per Pole

    2.5 amperes dc second location

  • Precious Material And Location

    contact surfaces silver

  • Body Length

    1.562 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    750.0 dc second location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 ac first location

  • Bushing Length

    0.365 inches minimum and 0.390 inches maximum

  • Thread Series Designator

    unef

  • Body Width

    1.281 inches maximum

  • Fragility Factor

    moderately rugged

  • Precious Material

    silver

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Mounting Surface To Terminal End Distance

    1.828 inches maximum

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    130.0 all locations

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Center To Center Distance Between Terminals Parallel To Length

    0.594 inches minimum and 0.656 inches maximum

  • Pole Quantity

    2

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac first location

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc second location

  • Reset Method

    manual

  • Frequency In Hertz

    400.0 first location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    5.000 maximum at 200 pct all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.594 inches minimum and 0.656 inches maximum

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Unpackaged Unit Weight

    2.100 ounces

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...