3XAM1516HKMG3-120VAC400C2

Circuit Breakers

CIRCUIT BREAKER

3XAM1516HKMG3-120VAC400C2

5925-00-950-5604

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Width

    3.060 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    2.060 inches nominal

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac

  • Circuit Protection Type

    overcurrent

  • Trip Release Characteristic

    time delay

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • Auxiliary Switch Function And Quantity

    1 control

  • Switch Location And Position Designation

    internal at pole three

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.300 minimum at 200 pct and 1.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Switch Current Rating And Type In Amps

    5.0 ac and 1.0 dc

  • Switch Voltage Rating And Type In Volts

    125.0 ac and 50.0 dc

  • Frequency In Hertz

    400.0

  • Test Data Document

    12909-400695 drawing

  • Body Length

    3.730 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    3.060 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    any acceptable

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Switch Contact Arrangement

    single pole,double throw

  • Boss Height

    0.160 inches nominal

  • Mounting Surface To Terminal End Distance

    3.250 inches nominal

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac

  • Trip Release Method

    magnetic

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0

  • Manual Actuator Type And Quantity

    3 toggle

  • External Actuator Linkage Arrangement

    one,two,and three linked

  • Internal Trip Release Configuration

    series trip

  • Nominal Thread Size

    0.138 inches

  • Switch Terminal Type

    tab,solder lug

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    6 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...